Support

Consumables & spares

The machine is bought once; the consumables keep it running. Original parts, shipped from Guangzhou on a repeat schedule.

Intervals

What wears out, and roughly when

Indicative figures under normal duty. A shop welding eight hours a day consumes lenses far faster than one welding two hours a week — treat these as planning numbers and inspect in between.

ConsumableTypical intervalWhat to know
Protective lens (focus lens window)Inspect daily; replace when spatter-damagedUnder normal duty a lens lasts around three months. Heavy spatter or a dirty gas line shortens that sharply — this is the part that protects a much more expensive optic behind it.
Copper nozzle / focusing nozzleAround six monthsWear shows up as an unstable bead and gas coverage problems before it shows up visually. Keep one spare on the shelf.
Filler wireConsumable per metre weldedCorrect diameter and alloy for the base material. Copper filler wire is not supported on this platform.
Shielding gasRoughly weekly in continuous useArgon or argon mix depending on material. Cylinder exchange is local; we advise on the regulator and flow setting.
Cooling water (water-cooled models)Check level weekly; change per scheduleUse purified or deionised water as specified — tap water scales the chiller and the repair costs more than the water ever will.

Do not run a lens until it fails. A damaged protective lens is cheap; the optic behind it is not. Keep one spare on the shelf.

What we stock

Original parts, no substitutes

Protective lens (focus lens window)

Protective lens (focus lens window)

Inspect daily; replace when spatter-damaged

Under normal duty a lens lasts around three months. Heavy spatter or a dirty gas line shortens that sharply — this is the part that protects a much more expensive optic behind it.

Copper nozzle / focusing nozzle

Copper nozzle / focusing nozzle

Around six months

Wear shows up as an unstable bead and gas coverage problems before it shows up visually. Keep one spare on the shelf.

Filler wire

Filler wire

Consumable per metre welded

Correct diameter and alloy for the base material. Copper filler wire is not supported on this platform.

Shielding gas

Shielding gas

Roughly weekly in continuous use

Argon or argon mix depending on material. Cylinder exchange is local; we advise on the regulator and flow setting.

Cooling water (water-cooled models)

Cooling water (water-cooled models)

Check level weekly; change per schedule

Use purified or deionised water as specified — tap water scales the chiller and the repair costs more than the water ever will.

Order consumables on WhatsApp

Tell us the model and what you need. We will confirm stock, price and the fastest shipping option — and set up a repeat schedule if you want one.

WhatsApp